United Electric Controls (UE), a market
leader in pressure switching technologies with hundreds of permutations for
diverse applications in virtually every industry has spawned unintended
consequences for users - too many models to choose from. The upshot of this is
a simple reliable switch is most likely available for your application. All you
need to do is follow the recommendations below and have UE select the ideal
switch for your needs.
How to Select a Pressure Switch
Pressure switches are widely used by many industries and within many
applications. The basic function of a pressure switch is to detect a pressure
change and convert it into an electrical signal function – typically on/off or
off/on. Pressure switches may be of electro-mechanical or electronic/solid-state
design; and while each may have its advantages, arriving at the correct pressure switch for your application is the same.
Set point & deadband
Application set point is the desired value reached at rising or falling pressure
at which the micro-switch changes electrical states. Depending upon the pressure switch function, the micro-switch could be wired to open or close when set point
is achieved thereby triggering an event such as an alarm, equipment shutdown, or
powering up secondary equipment. Ideally the set point should fall into the mid
50% of the pressure switch range for best performance including repeatability
and long life. On an electro-mechanical pressure switch, set point may be
adjusted internally or externally either through blind adjustment or reference
dial. An electronic pressure switch would have internal or external adjustment
via a key pad and digital display.
Deadband is the on-off differential required to reset the micro-switch. This
value may be fixed or adjustable with an electro-mechanical switch and may be up
to 100% adjustable on an electronic switch. Deadband may be an important factor
to consider depending upon the application requirements.
System pressure
Knowing your normal and maximum system pressures will help in selecting a
pressure switch with appropriate minimum and maximum operating parameters. Once
your set point is established, other factors to consider are vacuum and/or surge
pressure that could affect switch operation. This would involve maximum working
pressure, over range pressure, and proof pressure specifications of a pressure switch. The relationship between set point and system pressure has a direct
effect on switch performance and life.
Electrical considerations
Micro-switches are available in a variety of configurations. The most common for
electro-mechanical pressure switches is 15A, 480VAC SPDT (single pole, double
throw). The advantage of a SPDT micro-switch is that it offers wiring
flexibility to either open or close on pressure change. Other micro-switches
available include 1A with gold contacts, useful when working with a PLC, or at
the upper end, 30A when switching certain high voltage heaters or motors.
Adjustable micro-switches help with deadband adjustment. A DPDT (double pole,
double throw) micro-switch would provide two simultaneous functions off of one
micro-switch. If a low-high limit alarm and shutdown were required, there are
pressure switches that include two SPDT micro-switches that are independently
settable.
An electronic pressure switch would use solid-state relays to change states.
Like an electro-mechanical switch, the electronic switch can be programmed to
open or close on rising or falling pressure. There are different capacities for
switching voltage and current depending upon the application requirements.
Process media and wetted parts
The pressure connection and sensor are known as wetted parts since they come
into direct contact with the process media. Sensor material is either elastomer
(i.e. Buna-N, Teflon®) or metallic (i.e. Brass, Stainless Steel) with metallic
or composite pressure connections. The process media must be compatible with the
wetted parts material. Process media temperature should also be considered as
each of the different wetted materials would have differing operating
properties.
Pressure switch mounting
If the unit is to be installed directly onto the process, there are many methods
of installation. Typically a 1/8”, 1/4”, or 1/2” NPT (national pipe thread
taper) connection is used with a mating fitting to secure the pressure switch to
the process. There are also straight threaded (SAE, BSPT) connections, flush
mount connections, and sanitary connections. The pressure switch may be mounted
directly in the process line using the threaded connection, a manifold, or
flange; or the enclosure could be bolted to a mounting plate or other plane to
secure it. If heavy vibration is present, you may choose to use a remote
diaphragm seal with the pressure switch. The diaphragm seal mates with the
process connection while the pressure switch enclosure is mounted securely away
from the vibration.
Process environment
It is important to know what type of environment the pressure switch would be
installed in – hazardous or ordinary location; indoors or outdoors; exposed to
salt air; inside a control panel; in high ambient temperature. These are just
some of the factors to consider so the right enclosure type is chosen. Enclosure
types come in many shapes, sizes, and materials. They also conform to various
industry and third-party approval standards. Electronic switches can be used to
replace electro-mechanical switches when SIL is needed for safety applications.
There are also electro-mechanical pressure switches without enclosures;
typically used in OEM, non-hazardous locations where the environment is
benign.
With careful consideration of all the factors listed above, choosing a pressure switch is a snap.
Visit United Electric Controls (UE) Product
Selector to find your pressure switch.
If you would like more information like pricing and availablity about United Electric Controls (UE) Pressure Switches or other UE products please contact Forberg Scientific customer service.
Toll Free: 855-288-5330
Email: mechanicalsales@forberg.com
This comment has been removed by a blog administrator.
ReplyDeleteThis comment has been removed by a blog administrator.
ReplyDeleteI heard that for some amount of years the magnetic polars will switch but i am want to know how many years and when was the last time this occur? Thanks for sharing the useful information.
ReplyDelete