Don't Neglect Pressure Gauges

Inadequate attention can make plants vulnerable to mishaps

From: WIKA Jason Deane

The simple pressure gauge is an often-overlooked defense mechanism for preventing accidents. However, in auditing more than 250 plants, WIKA Instrument discovered that up to 25% of all pressure gauges were broken, damaged or misapplied — this represents an average of eight deficient gauges located within 20 feet of each employee.

A failed gauge compromises a plant's ability to detect a problem before a safety incident occurs. Malfunctioning gauges also can lead to media leaks, fugitive emissions and a fire or explosion, taking a toll on safety and reliability.

Even minor accidents can cause employee injury and lead to downtime. Any accident or leakage also puts staff sent to fix the problem into harm's way, which, of course, can lead to further employee injury and lost hours.

Many causes contribute to this dangerous situation with
gauges. Fortunately, they can be prevented.


CAUSES OF GAUGE FAILURE

Through its evaluation of more than 150,000 gauge installations, WIKA has identified eight common causes of failure. So, let's look at each, along with the solution.

1. Vibration. Many pieces of equipment vibrate. However, excessive vibration can lead to gauge failure and may indicate a problem with a component. Solution: install a gauge that will resist vibration better — i.e., a liquid-filled or direct-drive gauge with only a single moving part.

2. Pulsation. A rapidly cycling medium within a pressure system can make a
gauge pointer move erratically and eventually can lead to breakdown of internal parts. Solution: install a restrictor and liquid-filled case to dampen pulses on a standard gauge or replace with a direct-drive gauge that lacks gears and linkages.

3. Temperature. Extreme temperatures cause sweating and loosening in metal joints and eventually can cause them to crack. Solution: install a
gauge with a fully welded diaphragm seal and consider adding an on-board cooling element to combat the highest temperatures.

4. Overpressure and pressure spikes. Frequent pegging against the stop pin can bend the
gauge pointer and compromise the integrity of the Bourdon tube or sensing element and, ultimately, lead to rupture. Solution: install an overpressure protector to inhibit readings that exceed gauge capacity.

5. Corrosion. The highly corrosive media often found in process plants can damage the sensing material in
gauges. Solution: install a diaphragm seal that's constructed from material that will withstand the corrosive.

6. Clogging. A medium that contains suspended particles or is viscous or can crystallize can clog the pressure system and make
gauge readings unreliable. Solution: install a diaphragm seal with a clog-preventing barrier.

7. Steam. Some media produce steam or other vapors that can damage the internal parts of
gauges. Solution: install either a mini-siphon with an internal chamber to reduce surges or a full siphon, making sure to include a coil for horizontal applications and a pigtail for vertical ones.

8. Mishandling and abuse. Even properly installed
gauges will start to malfunction if mistreated over time. Solution: conduct regular safety and maintenance training for all employees who come into contact with or proximity to gauges.


Unfortunately, many plant personnel aren't properly equipped or experienced enough to recognize and address all these problems. That, however, doesn't reduce the importance of doing so.

TACKLING THE PROBLEMS

When beginning to address instrument shortcomings, keep in mind that studies show that fewer than 0.25% of piping components account for greater than 80% of controllable fugitive emissions. Installing gauges with welded diaphragm seals on these components creates a dual containment device, which is required by the U.S. Environmental Protection Agency. This means plants can correct a major source of violations and fines by addressing a very small percentage of connection points. For many facilities, this is an excellent place to start to get meaningful results quickly.

Another fairly straightforward step that's simple to implement but can yield powerful results is standardization of
gauges. This reduces the number of replacement parts that must be kept in inventory — and confusion by technicians. In other words, when replacing an old or faulty gauge, employees more likely will select the correct gauge rather than resorting to like and kind replacement. This also helps ensure the storeroom maintains proper inventory, helping cut costs.

Plants that don't have the resources to identify and correct faulty and misapplied
pressure measurement instruments can get outside help, such as from WIKA's FAST Team. Any audit team should:


• Visually evaluate the plant's gauge population and look for issues that need to be addressed.
• Diagnose
gauges that pose threats and uncover the causes.
• Formulate a strategic plan to address all the discovered issues.
• Audit the storeroom and streamline inventory, reducing redundant part numbers and guesswork.
• Provide dependable processes to prevent misapplying instruments in the future, and coordinate employee-training programs.


Given the complexity of managing the operations of a process plant, it's easy to understand how smaller components such as mechanical pressure instruments can be overlooked. However, using gauges as early warning devices can improve uptime, safety and profits. Money spent on the humble gauge very well could be the best investment a processing plant can make.

If you would like more information, pricing and availability on WIKA Pressure Gauges or other WIKA Instrument products please contact Forberg Scientific Customer Service.
Tool Free: 855-288-5330Email: mechanicalsales@forberg.com

Thursday, October 17, 2013

TopWorx GO Switch Hazardous Location Options

Emerson Process Management has increased the TopWorxGO Switch Hazardous Location Options

TopWorx is excited to announce new Haz Loc certifications to the GO Switch™ product line. Offering the best products for proximity switch and limit switch functionality:

   • GO Switch Models 11 & 21 with ATEX/IECEx Zone 0 Ex ‘ia’ certification
   • GO Switch Model 81 with ATEX/IECEx Zone 0 Ex ’ia’ certification
   • GO Switch Model 71 with ATEX/IECEx Zone 0 Ex ‘ia’ and Zone 1 Ex ‘d' certification

All GO Switch models are engineered to meet tough applications while offering high reliability and installation flexibility. These rugged, dependable, and affordable models are designed to operate in the following process industries with increased safety and lower installation cost:

   • Chemical and Petrochemical
   • Power
   • Food and Beverage
   • Municipal and Waste Water
   • Off-Shore Applications
 
All TopWorx GO Switch™ models offer higher reliability with increased safety and lower installation cost.

Visit us on-line at www.forberg.com or www.autoctrls.com .

If you have any questions or require additional information, please contact Forberg Scientific customer service.
Toll Free: 855-288-5330
Fax: 248-288-4204
Email: mechanicalsales@forberg.com

Thursday, November 1, 2012

UE One Series Seal Oil Skid Cost Reduction

UE ONE SERIES APPLICATION NOTE
One Series electronic switch reliably protects generator with I Am WorkingTM

UE One Series 2XLPA major electrical infrastructure company designs and manufactures power generation turbines that use natural gas, oil, coal and other fuel technologies. The company has standardized on One Series model 2XLP43 for measuring gage and differential pressure to replace traditional transmitters, UEmechanical switches and mechanical gauges on their seal oil skids.



THE PROBLEM:
The company needed to lower costs, reduce maintenance and provide more reliable hydrogen-cooled generators for their customers worldwide. In order to monitor pressure remotely, provide switch control and be able to instantly view pressure readings, three discrete instruments were needed – a pressure transmitter, a pressure switch and a local gauge. These three instruments were all connected to the same pressure source using the piping tree arrangement to the right.


Counting all of the tubing, elbows, t-fittings and connections to each instrument and the pressure source, potential leak paths quickly became a problem. Not counting block and bleed valves, there were a minimum of 12 threaded connections where the media could leak. The cost of the stainless steel tubing and fittings, the cost of the labor to plumb and leak-test and the maintenance required should clogging or leaking occur were all considered. Adding in the cost of the instrumentation and considering reliability, clearly a better method was needed.

THE SOLUTION:
The company needed a highly reliable instrument that could evaluate and report its own health status and provide the functions of the three instruments while reducing overall costs. The One Series 2XLP model is primarily a smart pressure transmitter with display that includes a programmable electronic switchswitch + gauge + transmitter all-in-one.

All One Series models include a self-diagnostic feature called I Am WorkingTM that monitors several vital instrument functions and reports health status three ways – locally on the digital display and remotely via the 4-20 mA analog and using discrete switch signals.

The One Series’ I Am WorkingTM feature watches for potential faults that could render the device unreliable. Unlike other blind instrumentation, the One Series can report detected faults with its own imbedded software, keypad, watchdog timer, power, switch and sensor. For example, if a clog occurs in an impulse line connected to the pressure sensor, the One Series can detect and report this fault before it becomes a larger problem – an undetected fault. In this case, the display will read “PLUG” while the switch opens (fail safe) and the 4-20 mA output saturates to 24 mA. The PLC evaluating these outputs then initiates an alarm or emergency shutdown, as appropriate.

For the company, the One Series carries worldwide hazardous location approvals and the units of measure are field adjustable, so no matter where in the world these seal oil skids land, the units of measure can be set to the local preference during commissioning. Reliability data is provided by a third-party failure modes and effects diagnostic analysis (FMEDA) report, available on UE’s website.

If you would like more information, pricing and availability on the UE One Series Switch or other United Electric Controls products please contact Forberg Scientific Customer Service.
Tool Free: 855-288-5330
Email: mechanicalsales@forberg.com