How to Select a Pressure Gauge

There are five primary items needed to properly select a pressure gauge:
  1. Pressure Range – What pressure scale needs to be measured?
  2. Dial Size – How large of a dial diameter is needed?
  3. Connection Type – What size and orientation of connection is required?
  4. Material – Should the wetted parts be brass or stainless steel?
  5. Accuracy – What accuracy of measurement is required?
1. Pressure Range
What pressure scale needs to be measured?  Generally speaking the gauge pressure span should be double the normal operating pressure of the application it is used on.  In other words, if the normal pressure of the system is 150 psi, you should select a pressure gauge with a 300 psi range.  If a gauge with the exact range is not available, it is best to round up.  For example, if the normal system pressure is 100 psi and a 200 psi range is not available, it is preferable to round up to a 300 psi gauge.

 
2. Dial Size
How large of a dial diameter is needed?  Dial size is simply the diameter of the circular face of the
pressure gauge.  When selecting a dial size, ease of reading and space available to mount the gauge are primary concerns.  Generally speaking, the larger the dial, the more expensive the pressure gauge.  The most common dial size is 2-1/2”.  Dial sizes can range from 1” up to 10”.
 

3. Connection Type
What size and orientation of connection is required?  The orientation of the connection refers to its location on the
pressure gauge.  Choices of orientation are generally lower mount (protruding from the bottom of the gauge at the six o’clock position) or back mount (protruding from the rear of the pressure gauge).  The vast majority of pressure gauges are sold with male pipe thread connections ranging in size from 1/8” NPT to ½” NPT with ¼” NPT being by far the most common.
 


4. Material
Should the wetted parts be made of brass or stainless steel?  The wetted parts of the
pressure gauge are the materials that come in contact with the fluid or gas being measured.  Stainless steel is more durable and more resistant to corrosion.  Brass is more economical.
 


5. Accuracy
What accuracy of measurement is required? 
Pressure gauges are available with accuracies ranging from +/- 3/2/3% to +/- 0.1% of span.  The higher degree of accuracy required, the more expensive a gauge will be.  Common accuracies are 2-1/2%, 1%, and 0.5% of span.

Forberg Scientific Tech Support

If you are looking for pressure gauges please contact Forberg Scientific, Inc. customer service. Forberg can help with selecting a pressure gauge that will meet your application need.
Toll Free: 855-288-5330
Email: mechanicalsales@forberg.com

Thursday, February 27, 2014

Mechanical Pressure Gauges Installation and Operating Instructions

Author: WIKA
From: WIKA Learning Center

Pressure Range Selection

To insure proper operation and long service life, the proper pressure range should be selected. For applications with constant, steady pressure, the measured pressure should be no more than 75% of the full scale range of the gauge. For applications with fluctuating pressure, the measured pressure should be no more than two-thirds of the full scale range of the gauge.

In general, it is best to choose a range that is roughly 2X the average measured pressure. This gives good over pressure protection and the highest accuracy.



Pressure Gauge Installation

The pressure gauge should be installed where exposure to heat and vibration are minimal and where the dial can be easily read. It is also important to install the gauge in a location with undisturbed and continuous flow of the pressure medium.

It is recommended that an isolating device, such as a needle valve or gauge cock, be installed between the process and the pressure gauges. This allows the gauge to be taken out of service without interruption of the process.

Connections with tapered threads, such as NPT, should be sealed by using PTFE tape (or an equivalent sealing compound) on the thread. Metric threads such as G1/4A or 1/4BSP should be sealed by using the appropriate sealing washer.

The gauge should be tightened and loosened using the wrench flats on the gauge socket. Never grasp the case to thread the gauge into the pressure system fitting. Doing so may cause irreparable damage to the gauge. For pressure gauges with flanged connections, care must be taken not to accidentally loosen the bolts that hold the upper and lower housings together.

A pressure gauge should never be removed when it is pressurized. Make sure the pressure system has been fully vented prior to removing a gauge.

Residues from the pressure medium may remain inside the pressure gauge after it has been removed from service. If these residues are hazardous or toxic, take the necessary precautions when handling and storing used gauges.

 

Isolating Devices

The isolating device may be either a pressure gauge cock or a needle valve, depending on operating conditions and requirements.

Pressure Gauge Cocks

Pressure gauge cocks have three handle positions:
OFF      The pressure medium is blocked and the
pressure gauge system is open to the atmosphere.
ON        The
pressure gauge is open to the pressure medium.
VENT   The
pressure gauge is isolated but the pressure system is vented and the medium can escape into the atmosphere.Pressure gauge cocks should be installed so that when vented, the pressure medium is directed away from the operator.

Pressure Gauge Needle Valves

Needle valves also isolate the pressure gauge from the pressure medium, but they usually do not have any venting capabilities. Needle valves do have the advantage of restricting the flow of the pressure into the gauge which helps reduce damage by pressure spikes.

Pressure Gauge Mounting Options

If the pressure system or tee-extension cannot support the weight of the instrument, then surface or wall mounting brackets or mounting flanges (front flange or rear flange) should be used.
 

Vibration Protection for Pressure Gauges

If the pressure gauge is exposed to vibration or pulsating pressure or both, then a liquid filled pressure gauge is recommended. The liquid dampens the effects of vibration making the pointer easier to read.

 

Pressure Gauge Temperature Limits

The pressure gauge should not be used outside of its rated temperature limits as noted on the Data Sheet specific to that gauge. At temperatures above or below these limits, the gauge accuracy will be significantly reduced and the possibility of gauge failure may exist.
 

Overpressure Limits on a Pressure Gauge

WIKA gauges are generally designed to withstand up to a 130% overpressure without damage to the pressure system. For applications with overpressure spikes, a snubber or restrictor should be used. Snubbers and restrictors reduce the inlet size of the pressure gauge which causes the pressure to increase or decrease more slowly into the gauge. For applications with periods of constant overpressure, an overpressure protector should be used. The overpressure protector isolates the gauge when the pressure reaches a preset pressure value.

Tee Extensions Guidelines for Pressure Gauges

Tee extensions should have a diameter of at least 0.24 in. (6mm) to avoid clogging from solids in the pressure medium. WIKA recommends that long, horizontal tee extensions be sloped to about 1:15.

With a gaseous pressure medium, the extension should having a drain plug at its lowest point, while a line with a liquid medium should have an air bleeding valve at its highest point. A filter or separator should be used when the pressure medium contains suspended matter.

If a static head of liquid is acting on the gauge, then this causes a zero offset which affects the reading of the gauge.

The corresponding indication will be lower by the value of Δp if the gauge is mounted above, but higher by the value of Δp if the gauge is mounted below the pressure tapping point.
 

Pressure Gauges in Service

Always open isolating devices slowly. Opening them too fast may generate sudden pressure surges that could damage the gauge.

Calibration can be confirmed in larger diameter gauges (> 4") by checking the position of the zero point. To do so, close the isolating device and vent the gauge to zero pressure. The pointer must over the zero box . Unless the gauge temperature is significantly higher or lower than 68°F (20°C), a pointer not returning to zero may indicate that the gauge has been seriously damaged.

Pressure Gauge Storage

The pressure gauge should remain in its original packing until installation.

Storage temperature should not exceed -4°F (-20°C) or 140°F (60°C) unless specified otherwise. Consult the data sheet pertaining to the pressure gauge model.

Pressure gauges removed from service should be protected from dust and humidity, preferably by using the original packing material. Residue from the pressure medium may remain in the gauge and is susceptible to temperature influences (i.e. freezing). This should be considered when storing the removed pressure gauge.
 

Pressure Gauge Safety

Pressure media such as:
  • Oxygen
  • Acetylene
  • Flammable gases or liquids
  • Toxic gases or liquids
  • Steam
  • Ammonia and other refrigerants
as well as portable or stationary pressure systems like:
  • Air compressors
  • Welding equipment
  • Pressure vessels and boilers
  • Life support equipment
may require pressure gauges that have been tested and/or certified to national standards and/or local safety codes. Your local WIKA representative will be able to assist you in selecting the proper gauge model.

Standards for Pressure Gauges

U.S. & Canadian Standards are set forth by The American Society of Mechanical Engineers, which publishes pressure gauge specifications in their document ASME B40.1. This document specifies standard pressure gauge types, sizes, materials, ranges, and accuracies. Copies of this standard can be purchased directly from ASME:
 
ASME
22 Law Drive, Box 2900
Fairfield, NJ 07007-2900
1-800-THE-ASME or (973) 882-1167
Fax: (973) 882-1717
E-mail:
infocentral@asme.org
 
European Standards are developed and published by the European Committee for Standardization (CEN) and replace the individual standards formerly used in each European country (such as DIN standards in Germany). Copies of these standards can be obtained through:
 
Comité Européen de Normalisation (CEN)
Central Secretariat
rue de Stassart 36
B-1050 Brussels
Belgium
 

Pressure Gauge Accessories

 
 
  1. Over Pressure Protector
  2. Throttling (adjustable) Snubber
  3. Adaptor for wall mounting bracket
  4. Needle Valves
  5. Coil Siphon
  6. Wall Mounting Bracket
  7. Thread Adaptor (1/4" NPT - G1/4A)


 

Recommended Pressure Gauge Orientation

The table below shows the recommended position for pressure gauges in typical applications.
 
 
If you would like to receive more information about WIKA pressure gauges please contact Forberg Scientific, Inc. customer service.
Phone: 855-288-5330


Monday, February 20, 2012

Advantages of Wika Liquid-filled Gauges

Liquid-filled gauges
Liquid-filled pressure gauges provide a number of advantages:

  • The liquid absorbs vibration and pressure spikes
  • The dampening action of the liquid enables the operator to
    take readings during conditions of rapid dynamic loading and
    vibration
  • The liquid lubricates all moving elements, dramatically
    reducing wear in the movement
  • Because most liquid-filled gauges are filled with non-aqueous
    liquid and hermetically sealed, they perform in corrosive environments
    and are immune to moisture penetration and icing
    and shock effects are lessened
Liquid-filled gauges enhance the reliability and integrity of the measuring system for long periods under extreme operating conditions.

Liquid-fill fluidAmbient Temperature Ratings (Table A)


Allowable operating range
Temperature range in which the operation of the gauge is not adversely affected by the filling liquid. At temperatures above the maximum rating, the fluid may break down. At temperatures below the minimum rating, the fluid may solidify (freeze).
Choose the right liquid
The type of liquid used to fill the gauge varies with the application. Although pure glycerine provides the best performance in most applications, each has its own requirements. Guidelines to help ensure that a fluid is properly matched to an application are:

  • If icing is a problem, use gauges filled with silicone oil or other comparable liquids. They have low viscosities even at -60C
  • If the system has electric accessories, such as contacts, use insulating oils
  • If extreme temperature fluctuations are expected, use silicone oils
The higher the liquid viscosity, the greater its dampening capacity. The reason for this is that dampening changes in proportion to the temperature-dependent viscosity of the filling liquid. The suitable degree of dampening depends on the operating requirements the gauge must meet, such as pointer response time, pressure extremes, vibration and changes in pressure. WIKA can recommend specific liquids to suit problem applications.

Liquid-filled gauge case venting
For pressure gauges with full scale ranges of 300 psi and below (including vacuum and compound ranges of 30" Hg-0-200 psi and below), case venting (after the gauge is installed) is necessary to preserve the accuracy. Temperature fluctuations during shipment and in the process application cause the liquid filling to expand and contract which in turn increases or decreases case pressure. As a result, accuracy can be decreased and the pointer may not return to zero properly until the gauge is vented to the atmosphere.

To vent a WIKA gauge, move the valve to the open position which will release any pressure or vacuum built up in the case. If the gauge is installed in an upright position, the lever can be left in the open position. The lever allows the use of a gauge in a non-upright orientation.

If you would like to get more information about WIKA pressure gauges or other WIKA products please contace Forberg Scientific, Inc. customer service.
Toll Free: 1-855-288-5330